Chapter 8 Parameters ASDA-A2
8-82 Revision February, 2017
P1-63 FRCT Friction Compensation
Address: 017EH
017FH
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0
Control
Mode:
PT/PR/S
Unit:
ms
Range:
0 ~ 1000
Data Size:
16-bit
Format:
Decimal
Settings:
Setup smoothing constant of friction compensation.
P1-64 PCCT
Analog Position Command: Activation
Control
Address: 0180H
0181H
Operational
Interface:
Panel/Software Communication
Related Section: N/A
Default:
0x00
Control
Mode:
PT
Unit:
--
Range:
0 x00~ 0x11
Data Size:
32-bit
Format:
Hexadecimal
Settings:
X:
0: Disable the function of position command which is issued by
analog
1: Enable the function of position command which is issued by
analog