ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-85
Data Size
16-bit
Format
Decimal
Settings
0: Disabled
Moving Filter can activate smooth function in
the beginning and the end of step command,
but it will delay the command.
P1-69 ~
P1-71
Reserved
P1-72 FRES
Resolution of Linear Scale for Full-closed
Loop Control
Address: 0190H
0191H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
5000
Control
Mode
PT
Unit pulserev
Range
200 ~1280000
Data Size
32-bit
Format
Decimal
Settings
A/B pulse corresponded by full-closed loop when motor runs a cycle
(after quadruple frequency)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2 Series and is the answer not in the manual?

Delta ASD-A2 Series Specifications

General IconGeneral
Control ModePosition, Speed, Torque
FeedbackIncremental encoder, Absolute encoder
Rated Output Power0.1 kW to 15 kW
Power Supply200-230V AC
Communication InterfaceRS-485, CANopen
Protection FeaturesOverload, Overvoltage, Overcurrent, Overheat