EasyManuals Logo

Delta ASD-A2 Series User Manual

Delta ASD-A2 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #354 background imageLoading...
Page #354 background image
ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-103
P2-26 DST Anti-interference Gain
Address: 0234H
0235H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0
Control
Mode:
ALL
Unit:
1
Range:
0 ~ 1023 (0: disable this function)
Data Size:
16-bit
Format:
Decimal
Settings:
Increasing the value of this parameter can increase the damping of speed
loop. It is suggested to set P2-26 equals to the value of P2-06. If users
desire to adjust P2-26, please follow the rules below.
1. In speed mode, increase the value of this parameter can reduce
speed overshoot.
2. In position mode, decrease the value of this parameter can reduce
position overshoot.
P2-27 GCC Gain Switching and Switching Selection
Address: 0236H
0237H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0
Control
Mode:
ALL
Unit:
-
Range:
0x0000 ~ 0x0018
Data Size:
16-bit
Format:
Hexadecimal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2 Series and is the answer not in the manual?

Delta ASD-A2 Series Specifications

General IconGeneral
Control ModePosition, Speed, Torque
FeedbackIncremental encoder, Absolute encoder
Rated Output Power0.1 kW to 15 kW
Power Supply200-230V AC
Communication InterfaceRS-485, CANopen
Protection FeaturesOverload, Overvoltage, Overcurrent, Overheat

Related product manuals