ASDA-A2 Chapter 12 Absolute System
12-22 Revision February, 2017
⑯
. If there doesn’t have any error occurred during communication course for the host controller to
finish bit 0 to bit 79 (80 bits data), the functions of DI4, DO2, DO3 will be changed back to their
original functions before communication cycle started.
NOTE
If ABSW does not go back to high level signal after the changing of ABSE for signal low to high
that is a sign of error occurring, there must be some other errors existing. Please check if the
coordinate data still there, the voltage level of battery, or overflowing on the coordinate value.
A new communication cycle can be started only all of these errors been removed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2 Series and is the answer not in the manual?

Delta ASD-A2 Series Specifications

General IconGeneral
Control ModePosition, Speed, Torque
FeedbackIncremental encoder, Absolute encoder
Rated Output Power0.1 kW to 15 kW
Power Supply200-230V AC
Communication InterfaceRS-485, CANopen
Protection FeaturesOverload, Overvoltage, Overcurrent, Overheat