DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP Operation Manual - Programming
3-458
Program example:
1. Input parameters starting from D4000: 2009/3/23/(y/m/d),10:10:30, Δt = 0, Local time zone = +8,
Longitude/Latitude = +119.192345 East, +24.593456 North, Elevation = 132.2M, Pressure =
820m, MAT = 15.0, Slope = 30 degree, Azimuth = -10 degree.
M0
DSPA D4000
D5000
M1013
2. Output results: D5000: Zenith = F37.2394 degree; D5002: Azimuth = F124.7042 degree.

Table of Contents