DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP Operation Manual - Programming
3-482
State 3: Current position at left side of zero point, pulse output in reverse, limit switch enabled.
Off
On
On
Off
On
Limit switch X5/X7
Limit switch ON
Off
Reverse
output
End flag
M1029/M1102
DOG switch: X4/X6
Freq.
Target freq.
JOG freq.
Time
Start
DOG switch ON
DOG switch OFF
Reverse
output
Forward
output
Limit switch OFF
State 4: Current position at right side of zero point, M1346=On.
Time
Freq.
X4
Start
Meet DOG
Left DOG
OnOff
Target speed
Jog speed
On
Off
M1029
Y4
Off
On
Time
Freq.
X4
Start
Meet DOG
Left DOG
OnOff
Target speed
Jog speed
On
Off
M1029
Y4
Off
On