DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP Operation Manual - Programming
3-582
API
Mnemonic
Operands Function
Controllers
ES2/EX2/
EC5
SS2
SA2
SE
SX2
296~
301
D
LDZ
Comparing contact type
absolute values LDZ
Type
OP
Bit Devices Word devices Program Steps
X Y M S K H KnX
KnY
KnM
KnS
T C D E F
LDZ: 7 steps
DLDZ: 13 steps
S
1
*
*
*
*
*
*
*
*
*
S
2
*
*
*
*
*
*
*
*
*
S
3
*
*
*
*
*
*
*
*
*
PULSE
16-bit
32-bit
ES2/
EX2/
EC5
SS2
SA2/
SE
SX2
ES2/
EX2/
EC5
SS2
SA2/
SE
SX2
ES2/
EX2/
EC5
SS2
SA2/
SE
SX2
Operands:
S
1
: Source device 1 S
2
: Source device 2 S
3
: Source device 3
Explanations:
1. DVP-ES2/EX2 series PLCs whose version is 3.20/DVP-SS2 series PLCs whose version is
3.00/DVP-SA2 series PLCs whose version is 2.60/DVP-SE series PLCs whose version is
1.20/DVP-SX2 series PLCs whose version is 2.40 (or above) are supported.
The absolute value of the difference between S
1
and S
2
is compared with the absolute value of S
3
.
Take LDZ= for example. If the comparison result is that the absolute value of the difference
between S
1
and S
2
is equal to the absolute value of S
3
, the condition of the instruction is met. If
the comparison result is that the absolute value of the difference between S
1
and S
2
is not equal
to the absolute value of S
3
, the condition of the instruction is not met.
The instruction can be connected to a busbar.
API No.
16-bit
instruction
32-bit
instruction
Comparison result
On
Off
296
LDZ
DLDZ
| S
1
- S
2
|
| S
3
|
| S
1
- S
2
| | S
3
|
297
LDZ>=
DLDZ>=
| S
1
- S
2
| | S
3
|
| S
1
- S
2
| | S
3
|
298
LDZ
DLDZ
| S
1
- S
2
|
| S
3
|
| S
1
- S
2
| | S
3
|
299
LDZ<=
DLDZ<=
| S
1
- S
2
| | S
3
|
| S
1
- S
2
| | S
3
|
300
LDZ
DLDZ
| S
1
- S
2
|
| S
3
|
| S
1
- S
2
| | S
3
|
301
LDZ<>
DLDZ<>
| S
1
- S
2
| | S
3
|
| S
1
- S
2
| | S
3
|
If the values of the most significant bits in S
1
, S
2
, and S
3
are 1, the values in S
1
, S
2
, and S
3
are
negative values.
A 32-bit counter (C200~) must be used with the 32-bit instruction DLDZ. If it is used with the 16-bit
instruction LDZ, a program error will occur, and the ERROR LED indicator on the PLC will
blink.