图5-21 Power vs Frequency参数对照
图5-22 P(V)页面
5.2.8.3. P(V)
此模式启动后,当市电电压大于V lock-in且此时逆变器之输出功率大于
P lock-in时,逆变器将会自动将输出功率降低至P lock-out,直到市电电
压低于V lock-out且经过T recovery秒后方回复正常功率输出。
Power Limit
Power vs. Frequency
P(V)
ENT
EXIT
EXIT
Mode
P lock-in
P lock-out
V lock-in
OFF
20%
5%
253.0V
V lock-out
T recovery
248.4V
300s