P
Pm
fstart =
f
(
Hz
)
Gradient
P
Pm
f
recovery
f
start
f
(
Hz
)
Gradient
Germany MV & ItalyOthers
f
recovery
f
protection
f
protection
圖5-21 Power vs Frequency參數對照
圖5-22 P(V)頁面
5.2.8.3. P(V)
此模式啟動後,當市電電壓大於V lock-in且此時逆變器之輸出功率大於
P lock-in時,逆變器將會自動將輸出功率降低至P lock-out,直到市電
電壓低於V lock-out且經過T recovery秒後方回復正常功率輸出。
Power Limit
Power vs. Frequency
P(V)
ENT
EXIT
EXIT
Mode
P lock-in
P lock-out
V lock-in
OFF
20%
5%
253.0V
V lock-out
T recovery
248.4V
300s
202
逆變器開機