4
Amplon RT Series
Features
z
True on-line design UPS protects your sensitive electronic equipment from power interruption.
z
Wide AC input voltage range (100Vac~300Vac) reduces frequent transfer
from on-line mode
to
battery mode to save battery consumption and prolong battery life.
z
Smart battery charger design performs auto-charging and reduces the charging time.
z
Automatic input frequency detection enables operation at 50Hz or 60Hz.
z
The input power factor correction and the high frequency pulse-width-modulated inverter give
the UPS excellent performance characteristics in this compact design.
z
Battery-Start powers on the UPS to provide stable AC power when there is no AC line avail-
able.
z
Remote Control Port: Use this port to either shut down the UPS completely (REPO) or switch
off the inverter only (ROO).
z
Built-in RS232 communication port allows the monitoring and management of the UPS via
SMART2000 software.
z
Optional accessories include
Mini SNMP
,
Mini Relay I/O
,
Mini USB
,
Mini ModBus
and
Mini
TVSS
cards for
network communication
, dry contact, USB communication, ModBus communi-
cation and surge protection.
z
State-of-the-art microprocessor technology performs self-detection and displays the UPS sta-
tus on LCD.
z
Surge protection and EMI  lter functions.
z
Automatic restart:
1) The UPS will restart in on-line mode automatically right after the AC line resumes following
a low battery shutdown.
2) The UPS returns automatically to on-line mode from bypass mode after the overload con-
dition is cleared.
z
External battery pack connector is provided to connect an external battery pack to extend the
backup time.
z
Optional ECO Mode: When the utility input voltage and frequency are
within the range of rating
voltage ±10% and rating frequency ±6%, the UPS will transfer to bypass mode; otherwise, the
UPS will transfer to on-line mode to reach higher ef ciency.
z
Auto-detect the bypass mode voltage: Automatically detects whether the bypass voltage is out of
rating voltage (240Vac output: 156~276Vac; 200/ 208/ 220/ 230Vac output: 156~264Vac). If yes,
the UPS will stop the supply to the load to protect your electronic equipment.
z
Automatically detects and shows whether the fan(s) is operating normally.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta RT5k and is the answer not in the manual?

Delta RT5k Specifications

General IconGeneral
BrandDelta
ModelRT5k
CategoryUPS
LanguageEnglish