Chapter 10 Digital Keypad|CFP2000 Series
10-10
Once the file name is confirmed, press ENTER key.
To begin copying parameters until it is done.
When copying parameters is completed, keypad will
automatically be back to this screen.
Press Right key to see the date of copying
parameters.
Press Right key to see the time of copying
parameters.
6. Fault record
Press ENTER key to select.
Able to store 6 error code (Keypad V1.02 and previous versions)
Able to store 20 error code (Keypad V1.03 and later version)
The most recent error record is shown as the first record. Select an error
record to see its detail such as date, time, frequency, current, voltage, DCBUs
voltage)
Press Up/Down key to select an error record.
A
fter selecting an error code, press ENTER to see
that error record’s detail
Press Up/Down key to see an error record’s detail
such as date, time, frequency, current, voltage,
DCBus voltage.
Press Up/Down key to select an error record.
A
fter selecting an error code, press ENTER to see
that error record’s detail
Press Up/Down key to see an error record’s detail
such as date, time, frequency, current, voltage,
DCBus voltage.
NOTE
Fault actions of AC motor drive are record and save to KPC-CC02. When
KPC-CC02 is removed and apply to another AC motor drive, the previous
fault records will not be deleted. The new fault records of the present AC
motor drive will accumulate to KPC-CC02.