Chapter 12 Description of Parameter SettingsMS300 (High Speed Model)
12-09-14
CANopen Control Status
Factory Setting: Read Only
Settings 0: Not ready for use state
1: Inhibit start state
2: Ready to switch on state
3: Switched on state
4: Enable operation state
7: Quick stop active state
13: Error reaction activation state
14: Error state
CANopen Reset Index
Factory Setting: 65535
Settings bit 0: CANopen reset, the internal address 20XX is 0
bit 1: CANopen reset, the internal address 264X is 0
bit 2: CANopen reset, the internal address 26AX is 0
bit 3: CANopen reset, the internal address 60XX is 0
Identifications for Communication Card
Factory Setting: ##
Settings 0: No communication card
1: DeviceNet Slave
2: Profibus-DP Slave
3: CANopen Slave
4: MODBUS-TCP Slave
5: EtherNet/IP Slave
10: Backup Power Supply
Firmware Version of Communication Card
Product Code
Error code
Factory Setting: ##
Settings Read only
Address of Communication Card
Factory Setting: 1
Settings DeviceNet: 0-63
Profibus-DP: 1-125