Error
Code
DPMS Update Error Display Details of Error code Remedies
12
U p d a t i n g f a i l 1 2
Abnormal data in Update Packet
received from CY920 (Packet No
Error).
Turn off and on the power. Updating
starts automatically.
13
E r a s e f a i l 1 3
Failed in Block Erase before rewrit-
ing Main.
Turn off and on the power. Updating
starts automatically.
14
U p d a t i n g f a i l 1 4
Failed in Block Erase while rewrit-
ing Main.
Turn off and on the power. Updating
starts automatically.
15
U p d a t e C h e c k N G 1 5
Error in Verify after rewriting Main
(Check Sum Error).
Turn off and on the power. Updating
starts automatically.
16
U p d a t i n g f a i l 1 6
Setup failure of the XModem
transfer method.
Check the network connection. Carry
out the update in an environment that
has little network load.
20
C o n n e c t i o n F a i l 2 0
After SBL Mode IP Address acqui-
sition failure (AutoIP).
Check the network connection. Carry
out the update in an environment that
has little network load.
21
C o n n e c t i o n F a i l 2 1
After SBL Mode IP Address acqui-
sition failure (Time Out).
Check the network connection. Carry
out the update in an environment that
has little network load.
22
L o g i n f a i l e d 2 2
DPMS login incorrect notication
after SBL.
Initialize the unit and try updating
again.
Carry out the update in an environment
that has little network load.
23
S e r v e r i s b u s y 2 3
DPMS congestion notication
after SBL.
Carry out the update in an environment
that has little network load.
24
C o n n e c t i o n F a i l 2 4
DPMS connection failure notica-
tion after SBL.
Check the network connection. Carry
out the update in an environment that
has little network load.
25
C o n n e c t i o n F a i l 2 5
Failed to transit to SBL Mode.
Initialize the unit and try updating
again.
26
D o w n l o a d f a i l 2 6
Error in Firmware Download (Time
Out).
Check the network connection. Carry
out the update in an environment that
has little network load.
27
C o n n e c t i o n F a i l 2 7
Failed to write to EEPROM after
SBL Mode.
Initialize the unit and try updating
again.
36
L o g i n f a i l e d 3 6
DPMS login incorrect notication.
Carry out the update in an environment
that has little network load.
37
S e r v e r i s b u s y 3 7
DPMS congestion notication.
Carry out the update in an environment
that has little network load.
38
C o n n e c t i o n F a i l 3 8
DPMS connection failure notica-
tion.
Check the network connection. Carry
out the update in an environment that
has little network load.
71