3.7 ELECTRICAL SYSTEM FAILURE
3.7.1 LOSS OF ELECTRICAL POWER
1. Battery circuit breaker.................. check, if tripped reset
2. ELECTRIC MASTER .................. check ON
If problem persists:
3. Land at the nearest suitable airfield.
END OF CHECKLIST
3.7.2 LOW VOLTAGE WARNING LIGHT ILLUMINATED
(a) Low VOLTAGE Indication on Ground
1. Propeller RPM ....................... increase RPM until VOLTAGE
warning light extinguishes
If low VOLTAGE warning light is still illuminated and the ammeter is indicating to the left
of centre (discharge):
- Terminate flight preparation.
END OF CHECKLIST