DV 20 E AFM
Emergency
Procedures
Doc. No. 4.01.25-E Rev. 2 22-Mar-2022
EASA
approved
Page 3 - 29
(b) Electrical Fire Including Smoke in Flight
1. ELECTRIC MASTER .................. OFF
2. Cabin air ............................ OPEN
3. Fire extinguisher ...................... use only if smoke development
continues.
CAUTION
If the fire extinguisher is used, the cabin must be ventilated
by opening the cabin air and the emergency windows.
WARNING
Never open the canopy in flight.
4. AVIONIC MASTER ................... OFF
5. Electrically powered equipment .......... OFF
NOTE
Restore electrical power systematically allowing time to
monitor the system ammeter between reconnection of loads.
Watch carefully for smoke.
In case the fire is extinguished and electric power is required for continuation of the flight:
6. ELECTRIC MASTER .................. ON
7. AVIONIC MASTER ................... ON
8. Radio .............................. ON
9. Land at the nearest suitable airfield.
END OF CHECKLIST