3.11.3 TRIM SYSTEM FAILURE
(a) Stuck Trim
1. Circuit breaker ....................... check, reset if necessary
2. Rocker switch ........................ depress in both directions,
wait 5 minutes, try again
NOTE
Full range of travel is available for elevator, but expect higher
forces on control stick.
3. Land at the nearest suitable airfield.
END OF CHECKLIST
(b) Runaway of Trim
1. Control stick ......................... Grip stick and maintain control
of airplane
2. TRIM circuit breaker ................... pull circuit breaker
3. Rocker switch ........................ check if depressed
If reason for runaway condition is obvious and has been resolved, reset (engage)
circuit breaker.
NOTE
Full travel of the elevator trim system will take approximately
10 seconds.