EasyManua.ls Logo

Digi XBee3 - C0 (Source Port); LA (Lookup IP Address of FQDN); Serial Interfacing Commands; BD (Baud Rate)

Digi XBee3
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AT commands Serial interfacing commands
Digi XBee3 Cellular LTE-M Global Smart Modem User Guide
113
Default
0x2616
C0 (Source Port)
Set or get the port number used to provide the serial communication service. Data received by this
port on the network is transmitted on the XBee Smart Modem's serial port.
As long as a network connection is established to this port (for TCP) data received on the serial port is
transmitted on the established network connection.
IP (IP Protocol) sets the protocol used when UART is in Transparent or APImode.
For more information on using incoming connections, see Socket behavior.
Parameter range
0 - 0xFFFF
Value Description
0 Disabled
Non-0 Enabled on that port
Default
0
LA (Lookup IP Address of FQDN)
Performs a DNS lookup of the given fully qualified domain name (FQDN) and outputs its IP address.
When you issue the command in API mode, the IP address is formatted in binary four byte big-endian
numeric value. In all other cases (for example, Command mode) the format is dotted decimal notation.
Range
Valid FQDN
Default
-
Serial interfacing commands
The following AT commands are serial interfacing commands.
BD (Baud Rate)
Sets or displays the serial interface baud rate for communication between the device's serial port and
the host.
Modified interface baud rates do not take effect until the XBee Smart Modem exits Command mode or
you issue AC (Apply Changes). The baud rate resets to default unless you save it with WR (Write) or by
clicking the Write module settings button in XCTU.
Parameter range
Standard baud rates:0x1 - 0x8

Table of Contents