Questions and Answers

  • H
    Hannah HorneAug 19, 2025
    What to do if there is occlusion in the IV tubing of DigiCare Pet Care Product?
    • M
      Madison EnglishAug 20, 2025
      If there is an occlusion in the IV tubing of your DigiCare Pet Care Product, check if the IV tubing is folded. Also, verify that the roller clamp is open and the needle is not blocked. If the IV set is too hard or large, consider replacing it or lowering the occlusion sensitivity.
  • N
    Nancy HansonAug 21, 2025
    Why are no drops detected in my DigiCare Pet Care Product?
    • S
      Sonya NicholsAug 22, 2025
      If no drops are detected by your DigiCare Pet Care Product, first, check if the solution container is empty. Second, examine the drop chamber for excessive fog drops or if the chamber is too tilted, causing the liquid to flow along the sidewall instead of dripping.
  • M
    michellewilcoxAug 23, 2025
    How to remove air from the tube in DigiCare DigiPump LP8?
    • S
      Stephanie MillerAug 25, 2025
      To remove air from the tube of your DigiCare Pet Care Product: 1. Open the pump door; the tube clamp will grip the tube automatically. 2. Remove the tubing above the tube clamp. 3. Tap the tubing to expel the air back to the drop chamber. 4. Reinstall the tubing and close the pump door to continue the infusion.
  • A
    Audrey JacksonAug 26, 2025
    What to do if the pump door is open on DigiCare Pet Care Product?
    • S
      Stephanie DavisAug 26, 2025
      If the pump door of your DigiCare Pet Care Product is open, make sure to close and lock it properly.
  • N
    Nicole SmithAug 27, 2025
    What to do if the battery voltage is low on DigiCare DigiPump LP8?
    • B
      bradleytinaAug 28, 2025
      If the battery voltage of your DigiCare Pet Care Product is low, promptly connect it to AC power or replace the battery with the same type.
  • A
    Antonio WilliamsAug 29, 2025
    How to clear alarm on DigiCare DigiPump LP8 Pet Care Product?
    • K
      Kathleen MurphyAug 30, 2025
      To clear the alarm on your DigiCare Pet Care Product, press the designated button.
  • A
    andrea26Aug 31, 2025
    Why is my DigiCare Pet Care Product leaking?
    • A
      Adrienne JacksonSep 1, 2025
      If you notice leakage with your DigiCare Pet Care Product: 1. Check whether the IV set is mounted correctly. 2. Check whether the drop detector is violently disturbed or shaken.
  • M
    Melissa ReyesSep 2, 2025
    Why DigiCare Pet Care Product can’t turn on?
    • P
      Paul JuarezSep 2, 2025
      If your DigiCare Pet Care Product doesn't turn on when you press the power button: * Reinstall the battery properly. * Connect to AC power and turn the rear panel switch on.
  • D
    davisangelaSep 4, 2025
    What to do if the battery failed on DigiCare DigiPump LP8?
    • C
      christinefitzgeraldSep 4, 2025
      If the battery has failed in your DigiCare Pet Care Product, check the battery connection or replace it with the same type of battery.
  • L
    Latasha VasquezSep 6, 2025
    What to do if the drop detector is disconnected from DigiCare DigiPump LP8?
    • K
      Kevin ConleySep 7, 2025
      If the drop detector is disconnected from your DigiCare Pet Care Product: 1. Check and ensure the drop detector is connected and mounted properly. 2. Check whether the connector is broken.