Section Five - Appendix
Reinitializing the RP14D
This option allows you to restore the contents of the RP14D’s memory to the original factory condition and calibrate the expression pedal.
ATTENTION: Performing this function will destroy all user-programmed data. All such data will be lost forever!
To restore the factory Programs and calibrate the expression pedal, the procedure is as follows:
1. Plug in the RP14D while holding down the Parameter Select Up button.
2. When reSt appears in the display window, release the Parameter Select Up button and press the Value Up button once. The RP14D
will reset to factory condition.
3. The display will now prompt you to re-calibrate the expression pedal by reading: PEDL CAL
4. When the display reads: toe up , rock the pedal back to the toe up position and press any one of the flashing footswitches.
5. When the display reads: toe dn , rock the pedal forward to the toe down position and press any one of the flashing footswitches.
The expression pedal will now be calibrated and the RP14D will return to program mode.
Recalibrating the Expression Pedal
If the Expression Pedal should fail to work, you can re-calibrate it by disconnecting the power, press and hold the Parameter Down button
and re-apply power. Release the button and repeat steps 3-5 as shown in the “Re-initializing the RP14D “ section above.