EasyManua.ls Logo

DIMA HC-100 - Specific; HC-1160; HC-1170 General; HC-1170 Specific

DIMA HC-100
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3 HYBRID Coater Service Manual ver1.1
24
The machine with serial number 601200600005 is not equipped with the push-button to allow
working with the hood open functionality (available from PC software version 1.2).
Machines with serial number starting from 600200700001 and 60120070001 are equipped
with a small vane at both the X and Y direction for guarding the XY positioning system.
Machines with serial number starting from 600200700003 and 60120070001 are equipped
with an exhaust detection sensor.
Machines with serial number 601200600002 – 601200600005, 600200700001 and
600200700002 have an electro panel according the revision 1.0 drawings with a control
circuit working on 230 VAC instead of 24VAC as all other machines have.
3.14.2 HC-100 Specific
All HC-100 machines (except 600200700002) are equipped with the EL-04879 Dispense
Head PCB. Machine 600200700002 has a wired solution.
3.14.3 HC-200 Specific
Machines with serial number 601200600002 – 601200600005 and 601200700001 are
equipped with the EL-04876 Dispense Head PCB. All other machines have the EL-04806
Dispense Head PCB. The new EL-04806 PCB has provision for temperature control of a
dispense valve and has other dimensions.
Machines with serial number 60120070002, 60120070006 and higher have the EL-04807
fiducial camera illumination placed (instead of the EL-04870) for improved fiducial recognition
(brighter light).
3.14.4 HC-1160/ HC-1170 General
Some of the first machines have conveyors with the first generation of stop pins. These are
no longer produced and replaced by a new generation. Assembling the new generation of
stop pins is done by force fitting. See Chapter 9 for specific information.
3.14.5 HC-1170 Specific
Machine with serial number 6002007002, has a HC-1170 conveyor build according the
revision 1.0 electrical drawings with a 3/2 valve for product clamping. All other machines
have a HC-1170 conveyor build according to revision 1.1 of the electrical drawing with a 5/2
valve for product clamping.

Table of Contents

Related product manuals