13
© 2019 Directed. All rights reserved.
BLUE and GREEN (-) Multiplex Sensor Trigger Input: These wires are
multiplex sensor trigger inputs. If a (-) input of less than 0.8 seconds is
supplied to either wire, a Warn Away response occurs. A (-) input of
longer than 0.8 seconds to either wire initiates the triggered sequence
and report Zone 4.
Parking Light Jumper
This jumper is used to determine the parking light output polarity. In the
(+) position, the on-board relay is enabled and the unit outputs (+)12V
on the White wire of the primary 12-pin harness. In the (-) position, the
onboard relay is disabled. The White wire supplies a 200 mA (-) output
suitable for driving factory parking light relays.
Note: For parking light circuits that draw 10 amps or more, the jumper
must be switched to a (-) parking light output. P/N 8617 or a standard
automotive SPDT relay must be used on the parking light output wire of
the primary 12-pin harness.
PARKING LIGHT
Important: DO NOT connect the parking light wire of the primary 12-pin
harness to a negative vehicle parking light wire before changing the pro-
gramming jumper to the negative polarity position or damage to vehicle light
circuit may occur.