Primary Harness - 12-pin connector
This guide describes in detail the connection of each wire. Also includ-
ed are possible applications of each wire. This system was designed
with the ultimate in flexibility and security in mind. Many of the wires
have more than one possible function. Please read carefully to ensure
a thorough understanding of this unit.
1
ORANGE (-) 500 mA GWA (Ground When Armed) OUTPUT
This wire supplies a (-) ground as long as the system is armed. This
output ceases as soon as the system is disarmed. The Orange wire is
pre-wired to control the 8618 starter disable relay. It can supply up to
500 mA of current.
Note: If using the this Orange wire to activate an add-on accessory
such as window automation, or voice module a 1-amp diode must be
installed to ensure proper operation. Insert the diode as shown in the
following diagram.
Important: Never interrupt any wire other than the starter wire.