19
© 2019 Directed. All rights reserved.
Feature Descriptions
System features are described below. Features that may only be
programmed with the XKLOADER3, as by this icon
Bitwriter PRG1000 XKLoader2XKLoader3
XKL
2
XKL
3
XKLoader3
®
.
Menu 1
1-1 Active/Passive Arming: With active arming the system arms using
the remote control only. When set to passive, the system arms auto-
matically 30 seconds after the last door is closed. The siren chirps 20
seconds after the door is closed to notify the user of Passive Arming.
At the 30 second mark, the system arms, but the siren does not chirp.
1-2 Siren Chirps ON/OFF: This feature controls the siren chirps that
confirm the arming and disarming of the system.
Bitwriter PRG1000 XKLoader2XKLoader3
XKL
2
XKL
3
XKLoader3
®
1-3 Ignition Controlled Door Locks ON/OFF: When set to on, the
doors lock three seconds after the ignition is turned on and unlock when
the ignition is turned off. If the door is open when the ignition is turned
on, the system will not lock the doors. The XKLOADER3 procedure for
ignition lock and ignition unlock may be programmed On or Off inde-
pendently.
1-4 Active/Passive Locking: If Passive Arming is selected in feature
# 1-1, you can program the doors to lock when Passive Arming oc-
curs, or program doors to lock when arming with the remote control.
With Active Locking the doors do not lock when the system is pas-
sively armed. When Passive Arming is selected, the system chirps 20
seconds after the last door is closed. Arming the system or locking the
doors occurs 30 seconds, after the door closes.