AUTOMATIC ENTRANCE SPECIALISTS
CE
EL 16
IP1895
rev. 2008-10-06
MIN
MAX
0% 100%
Os
30 s
60% 100%
0,1
m/s
BIS-TEN 0,8 mi.
REXVOL00,6m'3
0,1
m/s
BIS-TEN 0,8 mls
REX-VOL00,6m'3
5%
90%
12 V
12 V
+
Motor
VA
cr:
is
R1 Spinta sugli ostacoli
~ Thrust on obstacles
u1
Te
Tempo ehiusura autom.
Automatic closure time
Forza motore
RF
Motor thrust
Veloeita apre
Opening speed
VC Velocila ehiude
Closing speed
RP Apertura parziale
Partial opening
BIS- TEN-VOLO
REX
Abifitato
Disabilitato
Enabled
Disabled
Antipanico Continuo
Antipanic
Close
Chiusura Apertura
Closing Opening
Normale
Antipanico
Normal Antipanic
DIP1 Sensa di marcia
Movement direction
~ DIP2 lipo
automazione
m
Automation type
DIP3 Test sicurezza
Safety test
DIP1 Funzionamento battene
Batteries function
Ultima manovra
~ 'DIP2 con batterie, scariche
C
Last operation
with unloaded batteries
DIP3 lipo blocco
Lock type
GJ
Manuale di inslallazione quadro eletlronico per aulomazione
81S,
TEN, REX e VOLO.
@
Eleclric board installation handbook for
81S.
TEN, REX and VOLO automalions.
o
Manuel d'inslallation armoire electrique pour aulomalisme 81S, TEN, REX et VOLO.
o
Inslallalionsanleilung der TOrsleuerung
81S,
TEN, REX und VOLO.
CD
Manual de inslalaci6n del tablero eleclrico para aulomaci6n
81S,
TEN, REX
y
VOLO.
o
Manual de inslala<;ao quadro electrico para automa<;ao
81S.
TEN, REX e VOLO.
OFF ON
1
anta
dx/2 ante 1 anta sx
1 wing
rl/2
wings
1
wing left
Fig. 1
I
-'>
o
z~
BAT
ENC
BL
24 V
MOT
r::J
L:::=J
Fl
COM
F1 ; F1.6A (BIS-TEN-VOLO)
F1 ; F1A (REX)
COME
TELR
[Q]OPEN
1
lliJ
/DIR
~O
~O
~O
<DO
"'0
0>0
"'0
&lo
~O
~O
-10'
<:>
EL16
COMH-K
-8 ILAN4S
R1
LAN7S
0dJ LAB9
TELRS BIXLR22
Power reset
Esclusione blocco
I Lock exclusion
Comune parziale
I Paltial common
Stop
Sicurezza in chiusura
I Closing safety
$icurezza in aperture
I Opening safety
Chiusura
I Closing
Apertura lata B
I Opening side B
Apertura lata A
I Opening side
A
Chiusura automatica
I Automatic closure
Uscita
I Output
24 V=' 0,5 A
+
PASM24
DITEC S.pA
Via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY
Tel. +39 02 963911 - Fax +39 02 9650314
vvww.ditec.it - ditec@ditecva,com
lelM
ISO 9001
Cer!. n" 0957

Questions and Answers

  • G
    gregevansAug 4, 2025
    What to do if my DITEC Controller does not open and close?
    • B
      brookswilliamAug 4, 2025
      If your DITEC Controller is not opening and closing, here are a few things to check: * First, ensure the control panel has power. Look for the POWER ALARM LED; if it's off, there's no power. * Second, short-circuited accessories can cause this issue. Disconnect all accessories from terminals 0-1. A voltage of 24V= must be present. Then, reconnect them one at a time to identify any faulty accessories. * Third, a blown line fuse could be the culprit. Replace the transformer fuse. * Fourth, verify that the stop contact is closed. Check terminal 9 on the control panel and the position of the operations selector, if there is one. * Finally, ensure the door moves freely and isn't locked by bolts or locks.
  • J
    James AllenAug 10, 2025
    Why my DITEC Controller opens but doesn't close?
    • A
      albertjohnsonAug 10, 2025
      If your DITEC Controller opens but does not close, consider these potential causes: * The safety contacts may be open. Check terminals 6 and 8 on the control panel. Look for the SA LED being on. * The photocells might be activated, also indicated by the SA LED being on. Ensure the photocells are clean and working correctly. * Radars may be activated. Check that the radar is not subjected to vibrations, does not make false readings or the presence of moving objects within its range. * The automatic closing function might not be working. Check jumper 1-2 and the position of the operations selector, if one is present. * An incorrect DIP3 setting could be the issue, indicated by a flashing SA LED. Check the connections of the safeties.
  • T
    Teresa MooreAug 16, 2025
    What to do if DITEC Controller opens/closes briefly and then stops?
    • D
      donna70Aug 16, 2025
      If your DITEC Controller opens or closes briefly before stopping, the cause may be: * A defective encoder, indicated by a flashing POWER ALARM LED. If this is the case, replace the encoder. * Inverted motor wires, also indicated by a flashing POWER ALARM LED. Check the motor wires. * Friction. Manually check that the door wings move freely, and adjust the door wing height by lifting it.
  • O
    ohowardAug 21, 2025
    Why does my DITEC Controller open by itself?
    • E
      Elaine GarciaAug 21, 2025
      If your DITEC Controller is opening on its own, it could be due to unstable radars or radars detecting moving objects. Check that the radar is not subjected to vibrations, does not make false readings or the presence of moving objects within its range.
  • A
    Anita ThomasAug 28, 2025
    How to fix external safeties that do not activate on DITEC Controller?
    • K
      katherinemartinezAug 28, 2025
      If the external safeties on your DITEC Controller aren't activating, it might be due to incorrect connections between the photocells and the control panel. Connect the N.C. safety contacts together in series and remove any jumpers that may be present.

Summary

General Safety Warnings

Technical Data

Electrical Connections

Commands

Lists electrical commands and their functions for automation control.

Autocontrolled Safety Devices

Details the connection and function of automatic safety devices for door operations.

Outputs and Accessories

Describes the available outputs and accessories for the control panel, including power supply and battery.

DIR Connection

Explains how to connect the DIR card and its functions for additional control options.

Trimmers

Details the function and adjustment range of various trimmers for fine-tuning automation parameters.

Dip-Switches

Explains the configuration options set by DIP switches for direction, automation type, and safety.

Signals

Describes the status indicated by the LED signals on the control panel.

Starting

Troubleshooting

Application Example Without Selector

Application Example with COMH-COMK Selector

Application Example with COME Selector

Application Example with Autocontrolled Safety Device

Automations in Parallel

DITEC EL16 Specifications