EasyManua.ls Logo

DITEC LCA85 - User Manual

DITEC LCA85
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
UW
V016841
30 2 3 4 913G3
30 5 20
16R8R
UP
F1
DOWNENTERESC
Passo-passo
Finecorsa chiusura
Finecorsa apertura
Apertura parziale
LN
COM
SCI
30 1
30 1
JR1
J29
AUX1
AUX1
AUX2
AUX2
Antenna
uso futuro
11A0
12A
SCHEDA AD INNESTO
SCHEDA AD INNESTO
Alimentazione
230 V~
50/60 Hz
24 V~
230 V~ 25 W max
F5A
~
LP
Lampeggiante
Chiusura
automatica esterna
Apertura
Chiusura
Stop
Lampada stato
automazione
Uscita configurabile
Push button panel - PT3
(optional)
-
+
FUSE
Uscita 24 V
Arresto di sicurezza
Test sicurezze
Inversione di
sicurezza in
chiusura 8K2
Arresto di sicurezza
in apertura 8K2
Sicurezza in chiusura
COM
1~
R
X
R
A
D
I
O
ZENRS
ZENPRS
Ditec LCA85
Control panel installation manual for automations with
one 230 V~ motor
(translation of the original instructions)
IP2371EN • 2022-03-17
www.ditecautomations.com
Power supply
230 V~
50/60 Hz
Flashing light
230 V~ 25 W max
Opening limit switch
Closing limit switch
Step-by-step
24 V output
Partial aperture
Safety stop
Closing safety device
Safety devices test
Safety stop when
opening 8K2
Safety reversal
during closing
operation 8K2
Automation status
lamp output
Configurable 24 V
Automatic external
closure
Closure
Opening
Future use
PLUGIN BOARD
PLUGIN BOARD
respect
polarity L-N

Table of Contents

Questions and Answers

  • M
    Matthew PettyAug 15, 2025
    How to fix a DITEC LCA85 remote control with limited range?
    • C
      Cindy GonzalezAug 15, 2025
      If your DITEC Control Panel's remote control has a limited range, the issue might be due to radio transmission interference caused by metal structures or reinforced concrete walls. To solve this, install the antenna outside. Also, try replacing the transmitter batteries.
  • M
    Mark HallAug 20, 2025
    What to do if my DITEC LCA85 does not switch on?
    • C
      Christopher AdamsAug 20, 2025
      If your DITEC Control Panel fails to switch on, the issue may stem from the following: * **Power Supply:** Verify the power supply cable and the F1 fuse. * **Internal Fault:** It may require professional attention.
  • E
    eric27Aug 25, 2025
    Why is my DITEC Control Panel automation opening and closing briefly, then stopping?
    • J
      James SmithAug 26, 2025
      If your DITEC Control Panel automation opens and closes briefly before stopping, the cause may be friction. Manually check that the automation moves freely. Also check that the limit switches if installed, are working correctly. It may require professional attention.
  • G
    gilberttaylorAug 30, 2025
    What to do if my DITEC LCA85 remote control does not work?
    • C
      christine31Aug 30, 2025
      If the remote control for your DITEC Control Panel isn't working, it could be due to a missing or incorrect storage module. Turn off the automation and plug in the correct storage module. Also, check the correct memorisation of the transmitters on the built-in radio. If there is a fault with the radio receiver that is built into the control panel, the remote control codes can be read by removing the storage module.
  • I
    ivan17Sep 3, 2025
    How to solve external safety devices not activating on DITEC LCA85?
    • B
      boylemarkSep 3, 2025
      If the external safety devices on your DITEC Control Panel aren't activating, it might be due to incorrect connections between the photocells and the control panel. Check that / is displayed. Connect NC safety contacts together series and remove any jumpers on the control panel terminal board.
  • J
    Justin CooperNov 9, 2025
    What to do if my DITEC LCA85 Control Panel automation does not open or close?
    • L
      Luis CantrellNov 9, 2025
      If your DITEC Control Panel automation isn't opening or closing, several factors could be at play. Here's a breakdown of potential causes and how to address them: * **Power Issues:** Check the power supply cable and the F1 fuse. * **Short-Circuited Accessories:** Disconnect all accessories from terminals 0-1 or 0-30 (ensuring a 24 V voltage is present) and reconnect them one at a time to identify the culprit. * **Blown Fuse:** Replace fuse F1. * **Safety Contact Problems:** Ensure the safety contacts are correctly closed (NC). Also, check the connections to terminals 6-8 and the connections to the self-controlled safety edge. * **Photocell Issues:** Make sure the photocells are clean and functioning correctly. * **Safety Edge Issues:** Check the resistance values of the safety...

DITEC LCA85 Specifications

General IconGeneral
Power supply24 V DC
Resolution800 x 480 pixels
Operating SystemLinux
Weight1.5 kg
Touch ScreenYes
ProcessorARM Cortex A8

Related product manuals