42
IP2371EN
NOTE: make adjustments gradually and only after performing at least three complete oper-
ations to allow the control panel to be set correctly and detect any friction during operations.
Display Description Selections available
LU - Setting switch-on time for courtesy light (s)
To enable this parameter, set at least one of the selections
→
or
→ as a courtesy light.
It is set with different intervals of sensitivity.
NO - Disabled
- from 01” to 59” with intervals of 1 second
- from 1’ to 2’ with intervals of 10 seconds
- from 2’ to 3’ with intervals of 1 minute
ON - Permanently enabled (switched off via remote control)
NOTE: the courtesy light switches on at the start of each operation.
LG - Switch-on time for independently commanded courtesy light [s]
To enable this parameter, set at least one of the selections
→
or
→ as a courtesy light.
It is set with different intervals of sensitivity.
NO - Disabled
- from 01” to 59” with intervals of 1 second
- from 1’ to 2’ with intervals of 10 seconds
- from 2’ to 3’ with intervals of 1 minute
ON - Switched on and off with remote control
NOTE: the switching on of the light does not depend on the start of
an operation, but can be commanded separately using the special
remote control key.
PT - Fixed partial opening
ON - Enabled
OF - Disabled
If ON, a partial opening command given on the partial opening position is
ignored. With contact 30-20 closed (for example with the timer or manual se
-
lector), the gate will partially open. If it is then fully opened (command 30-3) and
reclosed (even with automatic closing), it will stop at the partial opening position.
DE - Disengagement duration if an edge is triggered [s]
Regulates the duration of the disengagement when an edge (active) is
triggered during opening or closure.
00 - Disable.
1.0
9.9.1 Additional configurable AP level parameters available with →
enabled
AP - Advanced parameters