10
IP1776EN 2012-02-20
LED On Flashing
IN
Receipt of command or change in status of
a dip-switch.
/
SA
At least one of the safety contacts is open. Safety test failure (terminal 41).
Operations count performed (only when con-
trol panel is switched on):
= 1000 operations
= 10000 operations
POWER ALARM
Power supply on. Incorrect selection of type of auto-
mation (jumper S1, S2, S3, S4).
NOTE: the signal lasts 10 s after which the
control panel is automatically reset.
Absence of motor or
incorrect selection of jumper OM.
NOTE: the signal lasts 10 s after which the
control panel is automatically reset.
7.1 Selection of automation type
Automation type S1 S2 S3 S4
Factory settings
N.C. N.C. N.C. N.C.
OBBI3BH, ARCBH N.O. N.C. N.C. N.C.
CUBIC30H, CUBIC6H N.C. N.O. N.C. N.C.
CUBIC30H+CUBIC30LI,
CUBIC6H+CUBIC6TC
CUBIC6H+CUBIC6TIG
N.C. N.O. N.O. N.C.
BOX3SH N.C. N.C. N.C. N.O.
ARC1BH, DOR1BH (recommended dimensions) N.C. N.O. N.C. N.O.
ARC1BH (limit dimensions) N.O. N.O. N.O. N.C.
DOR1BH (limit dimensions) N.O. N.C. N.C. N.O.
FACIL3H N.C. N.C. N.O. N.O.
DOKE N.O. N.O. N.C. N.C.
LUXO3BH, LUXO4BH N.O. N.O. N.C. N.O.
LUXO5BH (recommended dimensions) N.C. N.C. N.O. N.C.
LUXO5BH (limit dimensions) N.O. N.C. N.O. N.C.
Intelligent Security & Fire Ltd.