Output Value - Accessories Description
01
+
-
24 V= / 0.5 A
Accessories power supply. Power supply output for external ac-
cessories, including automation status lamp.
Electronically protected output.
1 13
24 V= / 3 W
Automation status lamp (proportional).
The light switches off when the automation is closed; the light
switches on when the automation is open; the light Àashes with a
variable frequency while the automation is operating.
0
14
LAMPH
24 V= / 25 W
Flashing light. With DIP6=OFF activated during opening and closing
operations.
Output protected by F2 fuse.
0
14
24 V= / 25 W
Courtesy light. With DIP6=ON an external courtesy light that turns
on for 180 s with every opening (total or partial), step-by-step and
closing command can be connected.
Output protected by F2 fuse.
0
15 24 V= / 300 mA
Electric block. It is activated when the automation is closed.
Output protected by F2 fuse.
0
15 12 V~ / 15 W
Electric lock. Connect the supplied 8.2 ȍ / 5W resistance in series.
Output protected by F2 fuse.
AUX1
AUX2
The control panel has two housings for plug-in cards such as a ra-
dio receiver type, magnetic loops, etc.
Plug-in card operating is selected using DIP1.
WARNING: the plug-in cards must be inserted and removed with
the power supply disconnected.
COM
DO NOT USE
BAT
BATKH
2 x 12 V / 2 Ah
Battery operating. The batteries are Nept charged when the power
supply is on. If the power supply is off, the control panel is powered
by the batteries until power is re-established or until the battery
voltage drops below the safety threshold. If this occurs, the control
panel turns off.
WARNING: the batteries must always be connected to the control
panel for charging. 3eriodically check the ef¿ciency of the batteries.
NOTE: the operating temperature of the rechargeable batteries is
approximately +5°C/+40°C.