5.1 SOFA1-SOFA2 self-controlled safety edge
Command Function Description
SOFA1-SOFA2
0411
SAFETY TEST Place the SOFA1-SOFA2 device into its housing for plug-in cards
AUX1 or AUX2.
With JR14=OFF, connecting terminal 41 enables a safety edge
test cycle before every operation. If the test fails the SA led Àashes
and the test is repeated.
1
6 N.C. OPENING
SAFETY
Connect the output contact of device to terminals 1-6 on the con-
trol panel (in series with the photocell output contact, if installed).
ATTENTION: make a jumper among 41-6 contacts if not used.
1 7 N.C. CLOSING
SAFETY
Connect the output contact of device to terminals 1-7 on the con-
trol panel (in series with the photocell output contact, if installed).
ATTENTION: make a jumper among 41-7 contacts if not used.
1
8 N.C. REVERSE
SAFETY CONTACT
Connect the output contact of device to terminals 1-8 on the con-
trol panel (in series with the photocell output contact, if installed).
ATTENTION: make a jumper among 41-8 contacts if not used.