7. ADJUSTMENTS
Description OFF ON
DIP1 Plug-in cards operation.
NOTE: it sets the operating mode of the
plug-in cards connected on AUX1 and
AUX2.
Step-by-step. Opening.
DIP2 Restore automatic closing time. 50% 100%
DIP3 Automation status at power on.
Indicates how the control panel considers
automation when powered up.
Open. Closed.
NOTE: if the automatic clo-
sing function is not used,
preferably set DIP3=ON.
DIP4 Electric lock release. Disabled. Enabled.
NOTE: when the electric lock
is installed, set DIP4=ON.
Electric block operation.
NOTE: only with EO=OFF.
Powered for the entire
opening and closing opera-
tion.
Powered only with the au-
tomation closed.
DIP5 3 seconds preÀashing. Disabled during opening.
Enabled only with automatic
closing with TC>3 s.
Enabled for both opening
and closing.
DIP6 Output 0-14 operation. Flashing light. Courtesy light.
Description OFF ON
FC Limit switch mode selection. Stop limit switch. Slow down limit switch.
SO Reversal safety switch function. With the automation blocNed,
if the contact 1-8 is open, it
is possible to activate the
opening operation.
With the automation blocNed,
if the contact 1-8 is open,
any operation is impossible.
EO Electric lock operation. Powered for 2.5 s at the
beginning of the opening
operation.
Powered for 1.2 s at the
beginning of the opening
operation.
OM Automation type. Automation with 1 motor or
with 2 motors in parallel.
Automation with 2 indepen-
dent motors.
FS FUTURE USE //
NIO Electronic antifreeze system.
Maintains motor function even at low am-
bient temperatures.
Enabled. Disabled.
JR14 Safety test terminal 41. Enabled. Disabled.