EasyManua.ls Logo

DMP Electronics 7872 - Wire the Electronic Lock; Wire the 333 Suppressor

DMP Electronics 7872
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Digital Monitoring Products, Inc. | 7800 Series Installation and Programming Guide 11
Wire the Electronic Lock
7873/7873H keypads provide a Form C (SPDT) relay for controlling locks and other
electronically-controlled barriers. The Form C relay draws up to 15mA of current and
the contacts are rated for 1Amp at 30VDC maximum, resistive. The wires marked NO
C NC allow you to connect the device wiring to the relay for module control. Use an
additional power supply to power magnetic locks and door strikes. See Figure 8 and
Figure 9.
Wire the 333 Suppressor
Use the included 333 suppressor with the keypad to suppress any surges caused
by energizing a magnetic lock or door strike. Install the 333 across the keypad C
(common) and NO (normally open) or NC (normally closed) wires.
If the device being controlled by the relay is connected to the NO and C wires, install
the suppressor on the NO and C wires. Conversely, if the device is connected to the
NC and C wires, install the 333 Suppressor on NC and C wires. See Figure 8 and
Figure 9.
4