15
Panic Icons
Optional panic functions allow users to send Police, Emergency, or Fire reports to the
central station. You must enable the panic function in Installer Options in order to use
the panic icons. Press the panic icon in the carousel menu to bring up the Panic Options
menu. This icon can be seen in Figure 7. Press the panic menu icon for 2 seconds until a
beep is heard. At the beep, the panel sends the following zone alarm reports to the central
station:
Panic - Zone 19 + Device Address
Emergency - non-medical - Zone 29 + Device Address
Fire - Zone 39 + Device Address
DISARMED
NOW
TUE
Panic
Chime
Check-in
Reset
MONITOR ON
Figure 7 and Figure 8: Graphic Keypad Panic Icons
Keypad Interface