Keypad Diagnostics
Keypad Diagnostics (KPD DIAG)
This option displays Zone Test.
Access the Installer Options Menu
Access the Options menu through the carousel menu. While
in the Option display, press the Installer Options icon and
enter the code 3577 (INST) at the keypad and press CMD.
Zone Test
This option allows the keypads to display the current
electrical status of the four protection zones. The status is
shown as OPEN, SHRT, or OKAY.
Note: The Zone Test displays on other keypads without
built-in zones, but is not operational.
Input Wiegand
This option tests the internal and external reader input from
proximity credentials. The display shows OKAY each time a
good proximity read is received.
Exiting the Installer Options (STOP)
Press the CMD key until the display returns to the Installer Options screen. Select STOP to
exit the Installer Options function.