5
EN
Range Troubleshooting
Troubleshooting Table
Operational Issue Potential Reason Page
The pilot will not light or stay lit. The gas pressure is too low. 20
The burner supply valve is closed. 12
The orifice is blocked. 14
The pilot assembly is blocked. 16
There is a blockage or kink in the pilot line. 16
The pilot flame is not engulfing the thermocouple. 24
There is an installation issue. 18
The gas system is leaky, damaged, or non-functioning. 13
The pilot is too close to the burner. 24
The burner is blocked. 12
The knob is not fully engaging the coil to set the magnet. 15
There is a problem with the oven thermostat. 15
The oven vent is blocked. 15
The air/gas mixture is incorrect. 14
The burner(s) will not light or stay lit. The burner is blocked. 12
The gas pressure is too low. 20
The air/gas mixture is incorrect. 14
The orifice is blocked. 14
There is a burner meltdown. 12
There is an installation issue. 18
The gas system is leaky, damaged, or non-functioning. 13
The burner(s) light, but the flame is too low. There is an installation issue. 18
The gas pressure is too high or too low. 20
The air/gas mixture is incorrect. 14
There is a problem with the burner supply valve. 12
The orifice is blocked. 14
The burner flame lis off of the burner head. The gas pressure is too high. 20
The oven bulb is not functioning properly. The bulb is defective. 25
The oven light switch is defective. 25
The connectors are improperly connected. 10
The wires are damaged. 25
The oven burner lights, but the flame remains
very low and the oven heats very slowly.
The burner is blocked. 12
The gas pressure is too high or too low. 20
The orifice is blocked. 14
The oven cycles frequently. There is a problem with the oven thermostat. 15
There is a problem with the thermal bulb. 17
The door is not sealing properly. 15