6500-065-J-7-18
23
1
ON SW1
2 3 4
REVERSE
LOOP
P2 P8
EXIT
LOOP
LMT
POWER
NC
TIME
DELAY
NO
REV SENSE
PRIMARY
4405-018
REV SENSE
SECONDARY
2
4
5
6
7
8
20
1
ON SW2
2 3 45 6 7 8
OB
CB
OE
CE
G
G
1
ON
1477-010
SW1
2 3 4
1
2
3
4
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
3.3 Limit Sensors
Magnetic sensor activator
must be directly above the
limit sensor to activate it.
P2 P8
EXIT
LOOP
Limit
Sensors
Plug
Not Used
Open
Close
Primary
Limit
Sensors
Secondary
Limit
Sensors
Close
Open
P2
Switch 1 “OFF”
SW 1
1
ON
2 3 4 5 6 7 8
SW 1
1
ON
2 3 4 5 6 7 8
PRIMARY Operator DIP Switch OPENING Direction
SW 1
1
ON
2 3 4 5 6 7 8
SW 1
1
ON
2 3 4 5 6 7 8
SECONDARY Operator DIP Switch OPENING Direction
Note: If P2 plug is not connected
to the circuit board and AC power
is turned on, alarm will sound
and operator will NOT function.
Operator Opens
Counter-clockwise
Switch 1 “ON”
Operator Opens
Clockwise
Switch 2 “OFF”
Operator Opens
Counter-clockwise
Switch 2 “ON”
Operator Opens
Clockwise
Dual Gate Operators Note: SW 1, switch 2 will be set the opposite
of SW 1, switch 1 (e.g. If switch 1 is OFF, then switch 2 will be ON).
Limit Sensor LEDs
Important Limit Sensor Adjustment Note:
It is very important NOT to cycle the gate operator
before the limit sensors are in the correct position or
it could cause damage to the gate and operator.
ONLY turn ON AC power. Manually release the gate
operator hub with the release tool (See page 33).
Physically move the gate to the desired open
position. Loosen the set screw on the OPEN limit
sensor and slowly slide it under the magnetic sensor
activator until the OPEN limit Sensor LED lights up
on the circuit board. Tighten the set screw and
repeat this process for the close gate position.
Secure the hub with the release tool and cycle the
operator a few times and readjust if necessary.
OPEN SENSOR
CLOSE SENSOR
Release Tool
Loosen set screw to
adjust the limit
sensor.
Magnetic Open
Limit Sensor
Magnetic Close
Limit Sensor
Magnetic Sensor
Activator
The hub must not slip
during operation. Tighten
nut to stop any slipping.
CAUTION
DO NOT REMOVE HUB!
CLOSE
OPEN
HUB