Gate Tracker - DoorKing Access Control System (Model 1833,
1835, 1837 or 1838) tracker system can be connected. This system
can keep track of gate operator cycle count, shorted inputs, loop
detector problems, any forced entry attempts, if the gate has struck
anything during the open or close cycle, power interruptions, etc.
For more detailed information refer to the Tracker Installation and
Wiring Manual, DoorKing P/N 2358-065.
#5 - Access Control
Devices
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Com
Com
Com
4.2 Control Wiring
Power is
limited to
250 mA
SW 1, switch 3 Must be ON.
#4 Com
24 Volt
1 amp max.
Stand-Alone
Key Switch
#4 - Safety
Opening
Device
Stand-Alone
Keypad
Stand-Alone
Card Reader
Telephone
Entry
4-Pin Non-Removable Terminal
Note: All stand-alone
and telephone entry devices
must use a separate power
source.
Note: When
using 3-button
control station
AND interlock
switch together,
#3 terminal
(N.C.) must be
wired in series.
3-Button Control Station
Use a standard 4-wire 3-button
control station. DoorKing’s
3-wire 3-button control station
CANNOT be used.
Normally Closed Interlock Switch
Radio
Open
#3 Stop N.C.
#2 Close N.O.
#1 Open N.O.
3-Wire
Radio
Receiver
To #4 Com
To #3 Stop N.C.
N.O.
N.C.
Com
Operator Cycling
Lock Engaged
N.O.
N.C.
Com
Operator Stopped
Lock Disengaged
OPEN
STOP
CLOS
E
SW 1
1
ON
2 3 4 5 6 7 8
Place jumper
on bottom
2 pins when
using 4-pin
terminal.
3-Pin With
Jumper
Magnetic Lock
#4 Normally Open
#5 Normally Open
#9 Normally Close
Quad Bo
x
Shown
Access
Device
Open
Safety
Open
24VDC
24VAC
Std
Reverse
Gate
Tracker
Gate
Tracker
Power (24-Volt DC) and logic
output. Power is shut off .5 sec.
prior to gate starting and
remains off while gate is
opening and in the
open position.
SW 2, switch 2 ON.
SW 2
1
ON
2 3 4
(2) Two 115 VAC
Convenience Outlets
Com
24 Volt
Relay
3-Pin
Remote
Terminal
123
UL 325 Terminal
See next page.
Orange
to main terminal #3
to main terminal #2
to main terminal #1
Brown
White
DANGER
HIGH VOLTAGE!
Terminal #3 Note:
Exceeding 250 mA of power from this terminal
may cause the circuit board transformer to
overheat, causing intermittent problems.
Important: Controls intended for user activation must be located at
least six (6) feet away from any moving part of the gate and where the
user is prevented from reaching over, under, around or through the gate
to operate the controls. Emergency access controls only accessible by
authorized personnel (e.g., fire, police, EMS) may be placed at any
location in the line-of-sight of the gate.
Type of wiring to be used on ALL external devices:
A) Type CL2, CL2P, CL2R, or CL2X.
B) Other cable with equivalent or better electrical,
mechanical, and flammability ratings.