OPERATING INSTRUCTIONS
17
7/71, 12/56
If the machine has been switched off for reasons of safety, then
ensure that the machine can be operated safely before restarting.
Refer to the PRIOR TO STARTING and STARTING THE UNIT
instructions earlier in this section before restarting the machine.
MONITORING DURING OPERATION
Should any of the safety shut-down conditions occur, the unit will
stop. These are:
. Low engine oil pressure
. High air discharge temperature
. High engine water temperature
CAUTION: To ensure an adequate flow of oil to the compressor at low
temperature, never allow the discharge pressure to fall below 3,5 bar.
DECOMMISSIONING
When the machine is to be permanently decommissioned or
dismantled, it is important to ensure that all hazard risks are either
eliminated or notified to the recipient of the machine. In particular:
. Do not destroy batteries or components containing asbestos
without containing the materials safely.
. Do not dispose of any pressure vessel that is not clearly marked
with its relevant data plate information or rendered unusable by drilling,
cutting etc.
. Do not allow lubricants or coolants to be released into land surfaces
or drains.
. Do not dispose of a complete machine without documentation
relating to instructions for its use.

Other manuals for Doosan 7/71