Maintenance Section
-241-
Every 1500 Service Hours or 9 Months
Inspect Ignition System (LP,
Gasoline & Dual Fuel Engines
Only)
1. Disconnect Battery Cables.
2. Remove and inspect the spark plugs. Replace
as required.
3. Test secondary cables with an Ohmmeter. If the
maximum resistance is higher than 25 kOhms,
repair and/or replace.
4. Inspect the ignition coil for cracks and heat
deterioration. Visually inspect the coil heat sink
fins. If any fins are broken replace as required.
G424I(E) Engine
G430FE Engine
G424P(E) Engine
(1) Spark Plug Cables
(2) Ignition Coil
Replace Spark Plugs (G430FE /
G424P(E) Engine Only)
1. Disconnect Battery Cables.
2. Using a gentle twisting motion remove the high
voltage cables from the spark plugs. Replace
any damaged cables.
3. Remove the spark plugs.
4. Gap the new spark plugs to the proper
specifications.
G430FE/G424P(E) Engine: 0.9 mm
5. Apply anti-seize compound to the spark plug
threads and install.
G430FE/G424P(E) Engine: 30 N·m (22 lb·ft)
WARNING
DO NOT OVERTIGHTEN THE SPARK PLUGS.
6. Re-install the high voltage cables.
2
1
2
1
2
1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Doosan D35C-5 FDA04 and is the answer not in the manual?

Doosan D35C-5 FDA04 Specifications

General IconGeneral
BrandDoosan
ModelD35C-5 FDA04
CategoryForklifts
LanguageEnglish

Related product manuals