Operating Manual Maintenance and Cleaning
WN 60425 45532/16458 - 08/2022 Solenoid Drop Bolt with manual Key Override 17
At DB25K the switch M is factory set for Fail Safe or Fail Secure configuration and
should not be changed.
Connection M position
Lock variant fail-safe (currentless opening)
Three-wire connection Off (default)
Two-wire connection - Not applicable -
Lock variant fail-secure (currentless closing)
Three-wire connection On (default)
Two-wire connection
Table6: Switch positions M
7 Maintenance and Cleaning
The lock has been factory lubricated for life and is maintenance free. The use of
other lubricants is not permitted and will void the warranty.
This lock contains electromechanical and electronic components that are subject
to wear and tear depending on use and on-site installation conditions. The
manufacturer has no influence on these factors. As a result of this wear, the lock
may fail at the end of its normal service life.
Maintenance and cleaning
Interval Activity
As needed: Using a dry cloth, polish the faceplate and strike
plate.
Note: Look for traces of dirt and wear (dust,
escaping lubricant).
Periodically, depending on
frequency of use (to be
determined by the operator):
Check for:
Tight fit
Smooth running
Noise during operation
Play of the latch
Contamination
Escaping lubricant
Moisture
If there are unusual noises, noticeable play,
escaping lubricant or similar, replace the lock.
Table7: Maintaining and cleaning the lock