EasyManua.ls Logo

dosatron D3 RE 10 - Limited Warranty

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
©
DOSATRON INTERNATIONAL / 55
EN
©
DOSATRON INTERNATIONAL / 55
©
DOSATRON INTERNATIONAL / 54
Limited warranty
DOSATRON INTERNATIONAL
S.A.S. will provide for replacement
of all parts shown to be defective
in material or workmanship during a
period of twelve months from the date
of purchase by the original purchaser.
To obtain warranty replacement of a
part, the DOSATRON must be returned
with original proof of purchase receipt
to the manufacturer or authorized
distributor and thereafter recognized
as defective after examination by the
technical services of the manufacturer
or distributor. The DOSATRON must
be flushed of any chemical and sent
to the manufacturer or distributor
prepaid, but will be returned free of
charge once repairs are made if found
to be covered by the warranty. Any
repairs made under warranty will not
extend the initial warranty period.
This warranty only covers
circumstances where the part has
failed due to defects caused by the
manufacturing process. This warranty
is invalid if the defects are found
to be due to the product’s misuse,
inappropriate use of tools, lack of
maintenance or defective installation
or environmental accidents or
corrosion by foreign bodies and
liquids found within or in proximity to
the DOSATRON.
Before using any aggressive
chemicals, please consult your
distributor to confirm compatibility with
the dosing pump.
The seals and “o-rings” are not
covered under warranty, nor is
damage to the DOSATRON caused
by water impurities such as sand.
A filter (ex.: 300 mesh - 60 microns
depending on your water quality) must
be used in front of the DOSATRON for
the warranty to be valid.
DOSATRON INTERNATIONAL
S.A.S. declines any responsibility
if the DOSATRON is not used in
compliance with the operating
instructions and tolerances as
indicated in this owner’s manual.
This warranty gives you specific
legal rights and you may also have
other rights which vary from state
to state. But any implied warranty
or merchantability or fitness for a
particular purpose applicable to this
product is limited in duration to the
time period of this written warranty or
any implied warranty.
There is no warranty express or
implied relating in any way to products
used in conjunction with DOSATRON
INTERNATIONAL S.A.S. products.
The manufacturer or authorized
distributor shall not be liable for
incidental or consequential damage,
such as any economic loss, resulting
from breach of this written warranty or
any implied warranty.
There are no warranties, express or
implied, which extend beyond those
described above.
THE MANUFACTURER
DECLINES ALL RESPONSIBILITY IF THE DOSATRON
IS USED IN CONDITIONS THAT DO NOT CORRESPOND
TO THE OPERATING INSTRUCTIONS AS INDICATED
IN THIS MANUAL
SYMPTOM CAUSE SOLUTION
Injection
Under injection. Suction of air. 1. Check the tightness
of the nuts in the
injection area.
2. Check suction tube.
Dirty or worn check
valve seal.
Clean or replace it.
Maximum
flow exceeded
(cavitation).
Reduce flow.
Worn plunger seal. Replace it.
Worn injection stem Replace it.
Leaks
Leaks in the vicinity
of the fixing ring
under the body
housing.
Injector sleeve
seal is damaged or
positioned incorrectly.
Replace it.
Leaks between the
setting sleeve and
the blocking ring.
Injector stem seal
damaged, positioned
incorrectly or
missing.
Replace it.
Leaks between the
body and screw-
top.
Screw-top seal is
damaged, positioned
incorrectly or missing.
Unscrew the screw-top,
clean the seal seating,
replace or change the seal.
Position correctly the
screw-top.

Table of Contents