EasyManua.ls Logo

dosatron D3 Series - Page 40

dosatron D3 Series
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
©
DOSATRON INTERNATIONAL S.A.S / 39
©
DOSATRON INTERNATIONAL S.A.S / 40
EN
Equipement
group
Equipment
category
Flammable
substances
Protection
level
Protection,
Faults
I
(Mining)
M1 Methane
Dusts
Very high 2 means of
protection or
2 independent
faults
M2 Methane
Dusts
High 1 mean of
protection
Normal operation
II
(Surface
Industry)
1 Gases,
vapours,
mists, dusts
Very high 2 means of
protection or
2 independent
faults
2 Gases,
vapours,
mists, dusts
High 1 mean of
protection
Ordinary and
frequent failure
3 Gases,
vapours,
mists, dusts
Normal Required level
of protection
Depending upon the nature of the
explosive atmosphere equipment
showing a suitable protection level
shall be used. The following diagram
sums up the appropriate equipment
groups and categories based on the
ATEX type:
User Directive
1999/92/CE
Manufacturer Directive
2014/34/UE
Gas
Atmosphere
Dust
Atmosphere
Zones Marking