CLEANING AND REFITTING THE SUCTION VALVE
WARNING: Before performing any work on the DOSATRON, you must
read to the Precautions section, page 15.
NOTA: Before dismantling, and to avoid any contact with the injected
additives, turn on the DOSATRON and allow it to draw in clear water in order
to rinse the injection assembly.
Turn off the water supply and allow the pressure to drop to zero.
Remove the suction hose (see Dismantling the suction hose, page 33).
Unscrew the suction valve locking nut.
Release the suction valve by pulling it through the middle of the injection
assembly
Thoroughly rinse the various parts of the valve using clear water.
Reassemble the parts following the order and positions shown in the
diagram.
D3IL10