EasyManua.ls Logo

Dräger Polytron 5100 - Physical and Environmental Specifications; Tightening Torque and Wiring Terminals

Dräger Polytron 5100
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28 Dräger Polytron 5100
Technical data
9.5 Physical specifications
Enclosure
material
copper free aluminum or 316 stainless steel
Enclosure
protection
NEMA 4X and IP 65/66/67
Display 4 digit, 9 segment, back-lit
Size (LxWxD,approx.)
Without Docking Station
11.3” x 5.8” x 5.1” (285 x 150 x 130 mm)
With Docking Station
11.5” x 7.1” x 7.4” (295 x 180 x 190 mm)
Weight (approx.)
Without Docking Station
aluminum 4.9 lbs. (2.2 kg)
stainless steel 316 8.8 lbs. (3.6 kg)
With Docking Station
aluminum 7.7 lbs. (3.5 kg)
stainless steel 316 11.9 lbs (5.4 kg)
9.6 Environmental parameters
Pressure 20.7 to 38.4 in. of Hg (700 to 1300 hPa)
Humidity 0% to 100% RH, non-condensing
Temperature -40 to +149 °F (-40 to +65 °C)
Storage
temperature
-4 to +149 °F (-20 to +65 °C)
See sensor data sheet for sensor specifications
9.7 Environmental influences
For influences on the measurement performance and
restrictions of a particular sensor see sensor data sheet.
9.8 Tightening torque for instrument threads
The values are valid for aluminum and stainless steel 316
versions.
Part TQ Lb. In. TQ Nm
Enclosure lid min. 44.3 min. 5
Sensor min. 266 min. 30
Blind plug min. 266 min. 30
Feed-through
Conduit hub
min. 443 min. 50
Instrument to
Docking Station
(4 screws)
71 8
Grounding screws 10.6 1.2
9.9 Tightening torque and size for field
wiring terminals
Terminal TQ Lb. In.
Wire Size
AW
G
Wire Size
mm
2
Power
supply and
signal
4.4 – 7.0
(0.5 – 0.8 Nm)
24 – 12 0.2 – 2.5
Relays
4.4 – 7.0
(0.5 – 0.8 Nm)
20 – 12 0.5 – 2.5
www.norrscope.com