For
your
safety
and
that
of
your
patients
For
your
safety
and
that
of
your
patients
Strictly
follow
the
Instructions
for
Use
Any
use
of
the
apparatus
requires
full
understanding
and
strict
observation
of
these
instructions.
The
apparatus
may
only
be
used
for
the
purposes
specified
here.
Maintenance
The
apparatus
must
be
inspected
and
serviced
every
6
months
by
trained
service
personnel.
Repair
and
general
overhaul
of
the
apparatus
may
only
be
carried
out
by
trained
service
personnel.
We
recommend
that
a
service
contract
be
obtained
with
DragerService
and
that
all
repairs
also
be
carried
out
by
them.
Only
authentic
Drager
spare
parts
may
be
used
for
maintenance.
Observe
chapter
"Maintenance
intervals”.
Accessories
Only
the
accessories
listed
in
the
enclosed
list
of
accessories
("Primus"
equipment
series
86 03
522,
Rev.
09
or
higher)
may
be
used.
Note:
Even
accessories
designed
to
be
reused
after
cleaning
have
a
limited
life.
Due
to
a
number
of
factors
connected
with
handling
and
preparation,
disinfectant
residues
can
attack
the
material
more
intensely
during
autoclaving;
increased
wear
can
occur
and
service
life
can
be
markedly
shortened.
Such
parts
should
be
replaced
when
external
signs
of
wear
become
apparent,
such
as
cracks,
deformation,
discoloration,
peeling,
etc.
Not
for
use
in
areas
of
explosion
hazard
This
apparatus
is
neither
approved
nor
certified
for
use
in
areas
where
combustible
or
explosive
gas
mixtures
are
likely
to
occur.
Safe
connection
with
other
electrical
equipment
Electrical
connections
to
equipment
which
is
not
listed
in
these
Instructions
for
Use
should
only
be
made
following
consultations
with
the
respective
manufacturers
or
an
expert.
10
Liability
for
proper
function
or
damage
The
liability
for
the
proper
function
of
the
apparatus
is
irrevocably
transferred
to
the
owner
or
operator
to
the
extent
that
the
apparatus
is
serviced
or
repaired
by
personnel
not
employed
or
authorized
by
DragerService
or
if
the
apparatus
is
used
in
a
manner
not
conforming
to
its
intended
use.
Drager
cannot
be
held
responsible
for
damage
caused
by
non-compliance
with
the
recommendations
given
above.
The
warranty
and
liability
provisions
of
the
terms
of
sale
and
delivery
of
Drager
are
likewise
not
modified
by
the
recommendations
given
above.
Drager
Medical
AG
&
Co.
KGaA
Instructions
for
Use
Primus
SW
2.n

Other manuals for Dräger Primus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Primus and is the answer not in the manual?

Dräger Primus Specifications

General IconGeneral
TypeAnesthesia Workstation
Oxygen FlushYes
Ventilation ModesPressure Support
Gas SupplyO2, Air, N2O
VaporizersIsoflurane, Sevoflurane, Halothane
Patient MonitoringAirway Pressure
Backup BatteryYes
AlarmsApnea, Gas supply failure
Power SupplyAC Mains, Battery Backup