Dräger Primus User Manual

Dräger Primus
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Drager
medical
A
Drager
and
Siemens
Company
Primus
Anaesthetic Workstation
Software
2.n
instructions
for
Use
Emergency
Care
-
OR/Anesthesia
-
Critical
Care
-
Perinatal
Care
-
Home
Care
Because
you
care

Other manuals for Dräger Primus

Question and Answer IconNeed help?

Do you have a question about the Dräger Primus and is the answer not in the manual?

Dräger Primus Specifications

General IconGeneral
TypeAnesthesia Workstation
Oxygen FlushYes
Ventilation ModesPressure Support
Gas SupplyO2, Air, N2O
VaporizersIsoflurane, Sevoflurane, Halothane
Patient MonitoringAirway Pressure
Backup BatteryYes
AlarmsApnea, Gas supply failure
Power SupplyAC Mains, Battery Backup

Summary

For your safety and that of your patients

Safety precautions

Essential guidelines for safe operation and patient care.

Strictly follow the instructions for Use

Emphasizes adherence to the manual for correct operation.

Before first use

Charging the battery for emergency operation

Instructions for charging the internal UPS battery.

Preparation

Connecting the gas supply

Steps to connect the workstation to medical gas sources.

Connecting the power supply

Steps for connecting the workstation to electrical power.

Getting started

Checking the workstation according to the check list

Procedure for verifying workstation readiness before operation.

Power on

Steps to switch on the workstation and initial boot process.

Self Test

Detailed explanation of the automated internal tests.

System compliance

How the workstation checks system performance and leaks.

Emergency start

Procedure for initiating operation in emergency situations.

Operation

Ventilation

Manual ventilation

How to perform ventilation manually using the device.

Controlled ventilation

Description of automated ventilation modes.

Synchronized volume-controlled ventilation

How ventilation synchronizes with patient effort for volume delivery.

Synchronized volume-controlled ventilation with pressure support (optional)

Ventilation synchronized with patient effort and pressure support.

Pressure mode, pressure-controlled ventilation

Ventilation controlled by pressure settings.

Synchronized pressure-controlled ventilation

Pressure-controlled ventilation synchronized with patient effort.

Synchronized pressure-controlled ventilation with pressure support (optional)

Pressure-controlled ventilation synchronized with pressure support.

Pressure support mode (optional)

Mode for patients breathing spontaneously with pressure assistance.

Changing patients

Leak test

How to perform a test to check for leaks in the breathing system.

End of operation

Steps to safely shut down the workstation.

Monitoring

SpO2 measurement (optional)

How to measure blood oxygen saturation.

Alarms

Alarm priorities and alarm signals

Explanation of alarm colors, sounds, and urgency.

Suppressing alarm

Procedures for temporarily muting or disabling alarms.

Limit-based alarms activated in respective ventilation modes

Table showing alarm status across different modes.

CO2 alarms on/off

How to enable or disable carbon dioxide monitoring alarms.

Displaying and setting alarm limits

How to view and adjust the thresholds for alarms.