Intended
use
Intended
use
Primus
Anaesthetic
Workstation
for
adults,
children
and
neonates
with
automatic
and
manual
ventilation,
as
well
as
spontaneous
breathing
with
or
without
pressure
support.
Utilizing
inhalation
anaesthesia
in
rebreathing
systems
Inhalation
anaesthesia
in
semi-closed
to
virtually
closed
systems
with
"low
flow"
and
"minimal
flow"
techniques
(for
minimal
gas
and
anaesthetic
agent
consumption)
Inhalation
anaesthesia
in
non+ebreathing
systems,
with
a
separate
fresh-gas
outlet
for
connecting
of
the
Bain
system
or
Magill
system,
for
example,
with
a
fresh-gas
flow
of
0.2
to
18
L/min.
Ventilation
modes
Volume-controiled
ventilation
in
volume
mode.
With
activation
of:
synchronization,
pressure
support
(optional)
Pressure-controlled
ventilation
in
pressure
mode
With
activation
of:
synchronization,
pressure
support
(optional)
Manual
ventilation
(Man.)
Spontaneous
breathing
(Spont.)
Pressure-assisted
spontaneous
breathing
in
pressure
support
mode
(optional)
The
following
measured
values
are
displayed
Peak
pressure
PPEAK,
mean
pressure
PMEAN,
plateau
pressure
PPLAT
and
PEEP
Expiratory
minute
volume
MV,
difference
between
inspiratory
and
expiratory
minute
volume
MVLEAK,
patient
compliance
CPAT,
tidal
volume
VT,
breathing
rate
Freq.
Inspiratory
and
expiratory
concentrations
of
O2,
N20,
anaesthetic
gas
and
CO2
AO2:
difference
between
inspiratory
and
expiratory
O2
concentration
Optional:
Functional
oxygen
saturation
(SpO2)
and
pulse
rate
The
following
parameters
are
displayed
as
curves
Airway
pressure
PAW
Inspiratory
and
expiratory
flow
Inspiratory
and
expiratory
concentrations
of
O2,
CO2
and
anaesthetic
gas
14
Optional:
Plethysmogram
p-V
loops
and
V-flow
loops
The
following
are
displayed
as
bar
graphs
Inspiratory,
expiratory
and
leakage
tidal
volume
Volumeter
Pressure
Econometer
for
indicating
fresh-gas
utilisation
(optional)
Trends
showing
the
measured
values
over
time
and
a
logbook
are
also
available.
Monitoring
by
means
of
adjustable
alarm
limits
which
can
automatically
be
adapted
to
the
momentary
ventilation
situation.
With
monitoring
for
Airway
pressure
PAW
Expiratory
minute
volume
MV
Apnoea
|
Inspiratory
and
expiratory
anaesthetic
gas
concentration
|
Detection
of
anaesthetic
gas
mixtures
(simultaneous
detection
of
up
to
two
anaesthetic
agents)
Inspiratory
O2
and
N2O
concentrations
Inspiratory
and
expiratory
CO2
concentrations
Special
alarm
response
in
HLM
mode
Optional:
Oxygen
saturation
Pulse
rate
instructions
for
Use
Primus
SW
2.n