Downlink Command: 0x06
Format: Command Code (0x06) followed by 3 bytes.
This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the
type code is 06.
Example 1: Downlink Payload:!06000000! !!!!!// Turn off interrupt mode
Example 2: Downlink Payload:!06000003! !!!!!// Set the interrupt mode to rising edge trigger
!
4.3! Get Firmware Version Info
Feature: use downlink to get firmware version.
Downlink Command: 0x26
Reply to the confirmation package: 26 01
Reply to non-confirmed packet: 26 00
Device will send an uplink after got this downlink command. With below payload:
Configures info payload:
Size(bytes)
1
1
1
1
1
5
1