07-01900G F413-230V AU BD2500 6 Legend Brands Holdings Ltd.
Recommended
Cordless drill, small knife, small-jaw pliers, coil clean-
ing solution, rotomolded housing cleaning solution.
Before each use
Inspect the electrical cord for damage. Look for fray-
ing, cuts, etc. Replace the cord if you find any damage.
Inspect filter. Replace if accumulation of dust and debris
is visible.
NOTICE: Replace used filters only with a new Dri-Eaz
filter part no. F583 (24-pack). Other filter types do not
provide adequate filtration or airflow.
IMPORTANT: Air filters should be replaced whenever
the accumulation of dust or debris is visible and after
every mold job.
Monthly
Inspect coils. Clean when dust accumulation is visible.
In normal use, dust can accumulate and can restrict air-
flow, reducing performance and causing the unit to over-
heat. Use a vacuum cleaner with a brush tool and a soft
cloth to remove any debris. Take care not to damage
any interior components.
To maintain appearance, wipe interior and exterior sur-
faces with a damp cloth. For deep cleaning and a last-
ing, protective shine, use an automotive interior cleaner.
As Needed
Clean pump check valve and basin. If the unit displays
the message “ER9 PUMP BLOCKED PUMP & HOSE”,
the pump check valve and pump basin may need to be
cleaned. Remove grills and cover as shown in Fig. B.
Remove screws from pump base and lift out pump. Wipe
out pump basin with a damp cloth. Unthread barbed fit-
ting with check valve and rinse fitting and check valve
with clean water. Reinstall barbed fitting into pump. Do
not overtighten. Reinstall pump on base. Reinstall cover
and grills. Clean coils. With the cover removed, inspect
both coils. If excessive dust and debris is present, vac-
uum thoroughly and/or clean with coil cleaner.