SYSTEM MESSAGES
The Control Panel will display the following messages based on system performance and environmental conditions. User
action, if any is required, is indicated in the third column.
MESSAGE
EXPLANATION USER ACTION
INITIALIZING Unit is powering up. None
Indicates control board firmware version number. None
Unit has finished powering up and is operating.
PLEASE WAIT
COMP. DELAY XX
60s delay before compressor turns on. Allows system
pressure to equalize.
None
UNIT ON XXXX HRS
INLET XXX°F / XX%
First line: indicates total operating hours.
Second line: Toggles between inlet temperature and in-
None
HUMIDISTAT
INLET XXX°F / XX%
First line: indicates unit is in humidistat mode
Second line: Toggles between inlet temperature and in-
None
LOW TEMP
INLET XXX°F / XX%
Unit shuts off if inlet temp below 45°F/7°C. Turns back
on when inlet reaches 50°F/10°C.
None
---
PUMP PURGING XX
Displays when the Pump Purge button is pressed.
Shows time remaining in seconds.
None
HI TEMP CYCLE
REMAINING XX MIN
Unit overload limit reached. Cool-down initiated. None
Unit is defrosting, with countdown in seconds. None
WAIT FOR
DEFROST XXX
Unit turned off when coil is cold or already in a defrost
cycle. Proceeds to finish cycle or initiate one to clear the
coils of ice before storage.
None
Occurs when unit is turned off and coil is not frozen.
Clears the coils of water before storage.
None
Prompt to check filter.
Check filter. Press the > key
to reset
Prompt to clean coils and interior.
Clean coils. Press the > key
to reset