TROUBLESHOOTING
FAULT CAUSE SOLUTION
Water drips out
when moving unit
Unit was unplugged before
purging was complete.
Purge unit before moving. See “At the End of the Job.”
Unit does not op-
erate
Unit not switched on.
No power to machine.
Switch unit on.
Plug in unit; check power cord connection at wall outlet.
Unit operating,
but room not dry
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Make sure “Humidistat” is OFF.
Allow more time for drying.
Increase air movement with air movers.
Seal off area to reduce infiltration.
Unit collects too
little water
Room air is dry.
Room temperature is too low.
Filter is clogged.
Coils are clogged.
Make sure “Humidistat” is OFF.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Replace as necessary.
Check coils. Clean as necessary.
If the problem you are experiencing is not listed here, call your local distributor.
SPECIFICATIONS
Name
Model F413-230V EU/UK
Dimensions (W × H × D) 31.8 × 45.7 × 54.6 cm
Weight (w/ cord & hose) 28.6 kg
Refrigerant 410A
Amps 3.5 amps at 26.7°C/60% RH
Power .81kW / 230V / 50Hz
Compressor rating 7050 BTU
Air movement 285 CMH
Water removal 38 L/day 26.7°C/60% RH
Operating temperature range 1–38°C
Sound level Does not exceed 70 dB
Safety CE
Specifications are subject to change without notice. Some values
PARTS INCLUDED
12 m drain hose with quick-connect fitting.
7.6 m power cord.
1 air filter
FILTER REORDERS
Air filter part no. F583 (24 pack)
OPTIONAL
Duct Attachment Kit (F530)
ADDITIONAL PRODUCT INFORMATION and current
documentation is available at
international.legendbrands.net.
FOR PARTS AND SERVICE contact your local distribu-
tor or Dri Eaz at +1 360 757 7776 – international.legend-
brands.net.